Service Standard
Item
Specification
Ignition Timing (°)
BTDC 6 ± 10
Idle Speed (rpm)
A/C OFF
Neutral, N, P-range
70 ...
Description and Operation
Refrigeration Cycle
...
Power Seat Motor. Repair procedures
Inspection
Power Seat Motor
1.
Disconnect the connectors for
each motor.A : Front height motor
B : Slide motorC : Rear height motor
D : Recline motorE : Lumber support motor
...