Kia Optima: Description and Operation
Operation
Function Of Safety Power Window
When all door (Front, Rear) power window auto-up
switch is operated, safety function is activated.
1. |
Safety function condition When
detect the force of 100N during the window rising, window is reversed.
|
2. |
Length of window reversing (except
holding the auto-up switch)
A. |
When detect the jamming
during the 4mm ~ 250mm from top of the door. → Window is reversed
until 300mm from top of the door.
|
B. |
When detect the jamming
over the 250mm from top of the door. → Window is reversed until
50mm from jamming position.
→ Window is reversed 50mm or bottom position in case of 50mm reversing
distance.
|
C. |
When detect the jamming
over 300mm from top of the door. → Window stops at reverse point.
|
|
3. |
Length of window reversing (holding
the auto-up switch)
A. |
When detect the jamming
during holding the auto-up switch. → Window is reversed until
25mm from jamming position.
|
B. |
Auto-up function is not
available during the 5 seconds from above condition. → When holding
the auto-up switch, window is operated as a manual-up function.
(Safety function is not activated.)
|
C. |
When detect the jamming
during holding the auto-up switch again. → Window is reversed
until 25mm from jamming position.
|
D. |
When holding the auto-up
switch after 5 seconds from above condition. → Window is reverse
until 25mm from jamming position.
|
|
4. |
Safety function is not available
area Safety function is not available during the 4mm from top of the door.
|
Normalization (Teaching)
After power on reset or error detection, the motor has
to be nomalized at the fully closed position.
How to be nomalized:
• |
Move the window upwards into
the fully closed position. As the window reaches the fully closed position,
hold the power window switch in auto for T≥2 seconds. If the block is
reconized, the system state turns to normalized.
|
Recall And Storing The Normalization (teaching) Information
ECU records the normalization
information into the specified location in Flash ROM. (as long as Flash ROM page
is valid)
• |
Stroing conditions : Entering
to sleep mode after valid switch input. Entering to low voltage(7.5V) after
valid switch input. |
• |
Recall conditions : Engine=ON
or Power ON reset |
Denormalization (Memory reset)
Under conditions below, ECU turns to denormalized
status. After demormalization, auto up and safety function shall not be operated.
In order to make these function active again, ECU should go through the mormalization
process.
• |
Denormalization conditions :
|
1. |
Continuous 15 times reverses |
2. |
Power off during motor operation |
3. |
Driver side door opened and window
glass is at the bottom (hard stop position) with IGN on, IGN off → within
2 sec, IGN on → Press Manual Down switch 3 times within 5 sec → De-normalization |
Door and Glass status
|
IGN status
|
Input time
|
IGN status
|
Switch input status
|
Switch input times
|
Normalization status
|
Re-input time
|
IGN status
|
Switch input
|
Driver side door opened, Window glass is bottom with IGN on (Hard stop)
|
IGN Off
|
T≤2 sec
|
IGN On
|
T≤5 sec
|
IGN On
|
Press and release Manual down switch
|
3 times
|
De-normalization
|
Window Position Control
To detect the window position and direction of motor rotation, hall sensors are
employed. ECU recognizes the fully closed position of the window and sets this relative
window position value as "0". When the window goes downwards, based on the information
from the hall sensor, the relative position value increments. On the contrary, when
the window goes upwards, it decrements.
Thermal Protection
Thermal protection by software module is implemented to prevent from destruction
of motor during overload condition. Motor temperature is estimated by integrating
squared motor current as an estimate for heating power integral. When estimated
motor temperature exceeds EEPROM programmable upper limit, motor is deactivated
for fixed delay time (default value = 30 sec.)
Thermal shutdown during a window
operation will not interrupt the operation due to safety reasons.
Operation Time Limiter
Maximal operation time of power window motor is limited
to 15 sec (EEPROM programmable).
Component Location
1. Driver power window main switch
2. Passenger power window switch
3. Front window motor
4. Rear window motor
5. Rear window switch
...
See also:
How to use this manual
We want to help you get the greatest possible driving pleasure from your vehicle.
Your Owner’s Manual can assist you in many ways. We strongly recommend that you
read the entire manual. In order t ...
Manifold Absolute Pressure Sensor (MAPS). Schematic Diagrams
Circuit Diagram
...
Troubleshooting
Troubleshooting
Problem Symptoms Table
Before replacing or repairing air conditioning components, first determine if the
malfunction is due to the refrigerant charge, air flow or compr ...