Inspection
1. | After disconnecting the vapor hose from the PCV valve, remove the PCV valve. Visually check for a collapsed vapor hose or hose leaks. |
2. | Reconnect the PCV valve to the vapor hose. |
3. |
Run the engine at idle, then put a finger over the
open end of the PCV valve and make sure that intake manifold vacuum
can be felt.
|
4. | If the vacuum is not felt inspect PCV operation, if operating correctly clean or replace the vapor hose. |
Installation
1.
The key of crankshaft should
be aligned with the mating face of main bearing cap. As a result of this,
the piston of No.1 cylinder is placed at the top dead center on compression ...
Cowl Top Cover. Repair procedures
Replacement
1.
Remove the cap (B) and remove
the nuts, then remove the wiper arm (A).
Tightening torque :22.6~26.5
N.m(2.3~2.7 kgf.m, 16.6~19.5 lb-ft)
...
Inspection
1.
Connect the GDS on the Data Link Connector (DLC).
2.
Measure the output voltage of the RPS at idle and
various engine speed.
Condition
...